POWER TRANSMISSION AND DISTRIBUTION EXPERIMENT SYSTEM

Kode : TML-1

Description

POWER TRANSMISSION AND DISTRIBUTION EXPERIMENT SYSTEM

Desription :

Using the Power Transmission Line trainer set it will be possible to assemble an absolute power transmission system. From a transformer with tapping switch to the power circuit breaker and 415V power transmission line model, including line termination with surge impedance. Various experiments can be are carried out on this power transmission system, no load operation with natural load, asymmetrical and asymmetrical short circuit, parallel and series compensation of the transmission line as well as neutral-point connection.

PRODUCT MODULE

THREE PHASE TRANSFORMER TL415KV
Transformer for feeding the transmission line model 415V. Scale factor 1:1000 for secondary current and voltage.
Nominal Power: 800VA. Primary: 3 x 400 V winding with tapping at 230V, can be switched to star or delta connection. Delta stabilizing winding can be connected. Secondary: 3 x 380 V winding with tap-pings at +5%, -5%, -10%, -15% in star connection, various star Point connections possible

TRANSMISSION LINE MODEL 415V
Measuring steady state operating conditions. Quad bundle 4 x 240/40, with surge impedance 240 and natural load 600 MW, length 360 km. Resistance: 13 Ohm, 8 Ohm, 5 Ohm. Inductance: 290 mH, 174 mH, 116 mH Open. Capacity: 5 µ F, 3 µ F, 2 µ F

INVERTER UNIT
3Ø asynchronous motor speed control by PWM technique. The Torque and Speed are able to be constant via the unit to easy control in testing operation during loads change. Input Voltage: 380V, 50Hz. Output Voltage: 0-380V.  Out Frequency: 1-300Hz. Max Power: 1.5 kW

THREE PHASE POWER SUPPLY
Fixed and variable AC supplies. Provided with start stop/stop push bottom EMO. Three Phase AC Adjustable Output : 3×0-380V: 6A. Three Phase AC Fixed Output: 240/415V: 10A. Power Requirement: 240/415V, 50Hz

RESISTIVE LOAD
Compose of three resistances with possibility to connect in star/delta or parallel, controlled by three switches with 7 steps variable per phase. Max Power: 1200 watt. Voltage: 415/240Volt (Star/Delta)

INDUCTIVE LOAD
Compose of three inductances with possibility to connect in star/delta or parallel, controlled by three switches with 7 steps variable per phase. Max Power: 900VAR. Voltage: 415/240Volt (Star/Delta)

Reviews

There are no reviews yet.